Technical Product Specification
Intel® Light Guided Diagnostics Intel® Server Board S1400FP TPS
Intel order number G64246-003 Revision 2.0
100
Color
State
Criticality
Description
3. Minimum number of fans to cool the system not present or failed
4. Hard drive fault
5. Power Unit Redundancy sensor – Insufficient resources offset
(indicates not enough power supplies present)
6. In non-sparing and non-mirroring mode if the threshold of
correctable errors is crossed within the window1
Amber
Solid on
Critical, non-
recoverable
Fatal alarm – system has failed or shutdown:
1. CPU CATERR signal asserted
2. MSID mismatch detected (CATERR also asserts for this case).
3. CPU 1 is missing
4. CPU ThermalTrip
5. No power good – power fault
6. DIMM failure when there is only 1 DIMM present and hence no
good memory present1.
7. Runtime memory uncorrectable error in non-redundant mode1.
8. DIMM Thermal Trip or equivalent
9. SSB Thermal Trip or equivalent
10. CPU ERR2 signal asserted
11. BMC\Video memory test failed. (Chassis ID shows blue/solid-on
for this condition)
12. Both uBoot BMC FW images are bad. (Chassis ID shows
blue/solid-on for this condition)
13. 240VA fault
Off
N/A
Not ready
AC power off
10.3
BMC Boot/Reset Status LED Indicators
During the BMC boot or BMC reset process, the System Status LED and System ID LED are
used to indicate BMC boot process transitions and states. A BMC boot will occur when AC
power is first applied to the system. A BMC reset will occur after: a BMC FW update, upon
receiving a BMC cold reset command, and upon a BMC watchdog initiated reset. The following
table defines the LED states during the BMC Boot/Reset process.
Table 50. BMC Boot/Reset Status LED Indicators
BMC Boot/Reset State
Chassis
ID LED
Status
LED
Comment
BMC/Video memory test failed
Solid
Blue
Solid
Amber
Nonrecoverable condition. Contact your Intel
®
representative for information on replacing this
motherboard.
Both Universal Bootloader (u
-
Boot) images bad
Solid
Blue
Solid
Amber
Nonrecoverable condition. Contact your Intel
®
representative for information on replacing this
motherboard.
BMC in u
-Boot
Blink
Blue
3Hz
Blink
Green
1Hz
Blinking green indicates degraded state (no manageability),
blinking blue indicates u-Boot is running but has not
transferred control to BMC Linux*. Server will be in this state
6-8 seconds after BMC reset while it pulls the Linux* image
into flash.
BMC Booting Linux
*
Solid
Blue
Solid
Green
Solid green with solid blue after an AC cycle / BMC reset,
indicates that the control has been passed from u-Boot to
BMC Linux* itself. It will be in this state for ~10-~20
seconds.
End of BMC boot/reset process.
Normal system
operation
Off
Solid
Green
Indicates BMC Linux* has booted and manageability
functionality is up and running. Fault/Status LEDs operate
as per usual.