20. Fault LED on 4x3.5” hot swap HDD cage may not function normally
during RAID rebuilding with AHCI ESRTII RAID configuration
Problem If system is configured as AHCI ESRTII RAID, HDD Fault LED may display “Off”
during RAID HDD rebuilding.
Implication You may observe HDD Fault LED steady off during rebuilding. No function
impact.
Status This issue may be fixed in a future ESRTII driver release.
Workaround None.
21. Integrated BMC Web Console – Sensor Readings Page – Memory
Throttling sensor status will stay “Critical” once triggered
Problem When Memory Throttling is triggered, the Memory “P1 MTT and/or P2 MTT”
sensor status will stay at “Critical” status in the Integrated BMC Web Console
even after throttling has stopped.
Implication You may observe Memory “P1 MTT and/or P2 MTT” status as “Critical” even
when there is no throttling. No functional impact to the system.
Status This issue was fixed in a ME 02.01.07.328 and later release.
Workaround Need a AC cycle or reset ME through IPMI to reset the MTT sensor status.
22. WOL (Wake on LAN) may not function under Red Hat* Linux 6.2 64bit OS
Problem With Intel
®
LAN driver version 17.1, WOL (Wake on LAN) may not function
under Red Hat* Linux 6.2 64bit OS.
Implication You may not be able to wake system through onboard NIC port.
Status This issue was fixed in Intel
®
LAN driver version 17.4 and later release.
Workaround None.
23. System only reports the first occurrence of power redundancy lost
events
Problem The integrated platform management subsystem will only report the first
occurrence of a power redundancy lost event. Any additional power
redundancy lost events that may occur after the initial event, will not be
reported unless an AC cycle of the server is performed.