Specification Update
Monthly Specification Update
6
Implication User may not able to install Microsoft Windows Server 2003* x86 on mentined
BIOS configuration.
Status This issue is fixed in RSTe driver release 3.0.0.3020-3 and later version
Workaround None.
8. System may halt under unsupported configuration in ESRT2 mode
Problem If no Intel
®
C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8,
RKSAS8R5) is installed to enable SAS support capablity under ESRT2 mode
while SAS drivers are used, the system may halt at the boot stage.
Implication User may see a system halt with no RAID keys installed with SAS drivers used
and ESRT2 enabled.
Status This issue is fixed in BIOS 1.3.0002 or later.
Workaround None.
9. Integrated BMC Web Console – Power Statistics page – Minimum
wattage reads as zero.
Problem On some systems the Integrated BMC Web Console Power Statistic page may
display the minimun wattage as zero (0W) after the system has been powered.
This reading will stay at zero until the next power cycle of the system.
Implication This is an incorrect reading only and does not affect operation.
Status This issue is fixed in BMC release 1.10.r3560 and later version
Workaround None.
10. Integrated BMC Web Console – Power Control page – Perform Action
button not functional.
Problem After performing a Graceful shutdown from the Integrated BMC Web Console
Power Control page the Perform Action button gets grayed out and cannot be
pressed to request another action.
Implication You cannot perform a power on of the system.
Status This issue is fixed in BMC release 1.10.r3560 and later version
Workaround Select another page in the Integrated BMC Web Console and then return to the
Power Control Page. The Perform Action button will then be available.