Service Guide

Server System Features
14 Intel
®
Server System R1000RP Service Guide
System Recovery Jumpers
Figure 11. Configuration Jumpers
Note:
1. For safety purposes, the power cord should be disconnected from a system before removing
any system components or moving any of the on-board jumper blocks.
2. System Update and Recovery files are included in the System Update Packages (SUP) posted
on http://www.intel.com/support/.
Table 6. Server Board Jumpers
Jumper Name
Pins
System Results
J3K6: BMC
Force Update
1-2
BMC Firmware Force Update Mode Disabled (Default)
2-3
BMC Firmware Force Update Mode Enabled
J2K8: BIOS
Recovery
1-2
Pins 1-2 should be jumpered for normal system operation. (Default)
2-3
The main system BIOS does not boot with pins 2-3 jumpered. The system only boots from EFI-
bootable recovery media with a recovery BIOS image present.
J2K6: BIOS
Default
1-2
These pins should have a jumper in place for normal system operation. (Default)
2-3
If pins 2-3 are jumpered with AC power plugged in, the CMOS settings clear in 5 seconds. Pins 2-3
should not be jumpered for normal system operation.
J3K2: ME
Force Update
1-2
ME Firmware Force Update Mode Disabled (Default)
2-3
ME Firmware Force Update Mode Enabled