Service Guide

Appendix C: LED Decoder
Intel
®
Server System R1000RP Service Guide 151
The following table provides a list of all POST progress codes.
Table 11. POST Progress Code Decoder
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED #
#7
#6
#5
#4
#3
#2
#1
#0
SEC Phase
01h
0
0
0
0
0
0
0
1
First POST code after CPU reset
02h
0
0
0
0
0
0
1
0
Microcode load begin
03h
0
0
0
0
0
0
1
1
CRAM initialization begin
04h
0
0
0
0
0
1
0
0
Pei Cache When Disabled
05h
0
0
0
0
0
1
0
1
SEC Core At Power On Begin.
06h
0
0
0
0
0
1
1
0
Early CPU initialization during Sec Phase.
07h
0
0
0
0
0
1
1
1
Early SB initialization during Sec Phase.
08h
0
0
0
0
1
0
0
0
Early NB initialization during Sec Phase.
09h
0
0
0
0
1
0
0
1
End Of Sec Phase.
0Eh
0
0
0
0
1
1
1
0
Microcode Not Found.
0Fh
0
0
0
0
1
1
1
1
Microcode Not Loaded.
PEI Phase
10h
0
0
0
1
0
0
0
0
PEI Core
11h
0
0
0
1
0
0
0
1
CPU PEIM
15h
0
0
0
1
0
1
0
1
NB PEIM
19h
0
0
0
1
1
0
0
1
SB PEIM
MRC Process Codes MRC Progress Code Sequence is executed
PEI Phase continued…
31h
0
0
1
1
0
0
0
1
Memory Installed
32h
0
0
1
1
0
0
1
0
CPU PEIM (CPU Init)
33h
0
0
1
1
0
0
1
1
CPU PEIM (Cache Init)
34h
0
0
1
1
0
1
0
0
CPU PEIM (BSP Select)
35h
0
0
1
1
0
1
0
1
CPU PEIM (AP Init)
36h
0
0
1
1
0
1
1
0
CPU PEIM (CPU SMM Init)
4Fh
0
1
0
0
1
1
1
1
Dxe IPL started
DXE Phase
60h
0
1
1
0
0
0
0
0
DXE Core started