Service Guide
Appendix A: Technical Reference
Intel
®
Server System R1000RP Service Guide 147
Appendix A: Technical Reference
System Environmental Specifications
The following table defines the system level operating and non-operating environmental limits.
Table 9. System Environmental Limits Summary
Parameter
Limits
Temperature
Operating
ASHRAE Class A2 – Continuous Operation. 10ºC to 35ºC (50ºF to 95º F)
with the maximum rate of change not to exceed 10°C per hour
ASHRAE Class A3 – Includes operation up to 40ºC for up to 900 hrs per
year.
ASHRAE Class A4 – Includes operation up to 45ºC for up to 90 hrs per
year.
Shipping
-40ºC to 70ºC (-40ºF to 158ºF)
Altitude
Operating
Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping
50% to 90%, non-condensing with a maximum wet bulb of 28°C (at
temperatures from 25°C to 35°C)
Shock
Operating
Half sine, 2g, 11 mSec
Unpackaged
Trapezoidal, 25g, velocity change is based on packaged weight
Packaged
Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged
5 Hz to 500 Hz 2.20 g RMS random
Packaged
5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage
90 Hz to 132 V and 180 V to 264 V
Frequency
47 Hz to 63 Hz
Source Interrupt
No loss of data for power line drop-out of 12 mSec
Surge Non-operating
and operating
Unidirectional
Line to earth Only
AC Leads 2.0 kV
I/O Leads 1.0 kV
DC Leads 0.5 kV
ESD
Air Discharged
12.0 kV
Contact Discharge
8.0 kV
Acoustics Sound
Power Measured