Specification Update
Monthly Specification Update
Summary Tables of Changes
The following tables provide an overview of known errata and known document changes that
apply to the specified Intel Server Products. The tables use the following notations:
Doc
Intel intends to update the appropriate documentation in a future revision.
Fix
Intel intends to correct this erratum.
Fixed
This erratum has been corrected.
No Fix
There are no plans to correct this erratum.
Shaded
This item is new or has been modified from the previous specification update.
Table 1. Errata Summary
No.
Plans
Description of Errata
1
Fixed
BIOS setting is locked after running “syscfg/bldfs” to load BIOS default setting.
2
Fixed
Admin Password is cleared after loading user defaults.
3
Fixed
By using LSI* SCSI storage card 20320 can’t enter into Microsoft Windows 2008* R2.
4
Fixed
Intelligent Platform Management Bus (IPMB) functions on devices connected to IPMB connector might
not be available on Intel
®
Server Board S1200BTL.
5
Fixed
Unable to install SLES* 11 Service Package 1 to iSCSi drive from onboard Intel
®
82579 network card.
6
No Fix
Node Manager does not work with Intel
®
Core
™
Processor i3-2100 series
or Intel
®
Pentium
®
Processor.
7
Fixed
Intel
®
Integrated RAID Module SRMS2LL040 does not work.
8
Fixed
Memory Mapped I/O above 4 GB option can’t map 64bit addresses.
9
Fixed
Windows 2008* R2 can’t be installed properly or the OS will hang with NIC ROM disabled in BIOS.
10
Fixed
The SGPIO cable is not compatible with Intel
®
SAS Entry Raid Module AXX4SASMOD, Intel
®
Integrated RAID Module SRMS2AF040 and Intel
®
Integrated RAID Module SRMS2LL040.
11
No Fix
When EULOT 6 is enabled, the system can’t boot up by press power button once.
12
Fixed
The value of SMI BIOS type 17 is not correct.
13
Fixed
BMC user SOL payload enable/disable status can’t be saved across BMC reset.
14
Fixed
SOL activation is failed when Console Redirection is disabled in BIOS Setup.
15
Fixed
The 4
th
HDD cage interferes with the right side rack handle screws on then Intel
®
R1304BTLSHBN.
16
Fixed
Microsoft* Windows SBS 2011 Essential doesn’t recognize ESRT2 driver during installation.
17
Fixed
System may hang about 20 seconds during system rebooting.
18
No Fix
Some Function Keys does not work through SOL session.
19
Fixed
Keyboard does not work under EFI if USB flash disk is inserted/removed when enabled TXT in BIOS.
20
Fixed
When using Hardware RAID controller, pressing “Ctrl+G” cannot enter RAID configuration utility.
21
Fixed
The RPM of three fans on Intel
®
Server System R1304BTLSHBN drops to 0 sometimes after AC cycle.
22
Fixed
PCT reports "Processor Does Not Support Brand ID."
23
Fixed
The SEL is keep reporting when RAID is rebuilding on Intel
®
Server System R1304BTLSHBN.
24
Fixed
The system cannot detect more than 8 USB devices.
25
No Fix
USB Keyboard mouse cannot wakeup the system from the Standby mode.
26
Fixed
The NMI button on front panel does not work as expected.
2