Specification Update

Monthly Specification Update
Implication Cannot create NMI interrupt through the NMI button on front panel.
Status Fixed in BIOS Rev.35
Workaround None.
27.
Consistency Check in S1200BTL/S1200BTS motherboard’s ESRT2
OpROM Configuration Utility returns error message
Problem Consistency Check in S1200BTL/S1200BTS motherboard’s ESRT2 OpROM
Configuration Utility returns error message.
Implication The screen may pop up message “Error In Reading Sectors To Drive0 !
Proceed Anyway (Y/N)?”. If Y is pressed, the screen may pop up the same
message after a while. The Consistency Check may not complete successfully.
User has to abort the Consistency Check.
Status No Fix. Consistency Check algorithm is very low level under ESRT2 OpROM
Configuration Utility, and not compatible with some drives.
Workaround In the operating system environment, use Intel
®
RAID Web Console 2 to
implement Consistency Check. The failure to complete Consistency Check
during ESRT2 OpROM Configuration Utility doesn’t impact normal usage under
operating system environment.
28.
There is no driver for Intel
®
82579 network card on VMWare ESXi* 5.0,
VMWare ESXi* 4.1 Update 1 and VMWare* ESX 4.1 Update 1
Problem There is no driver for Intel
®
82579 network card on VMWare ESXi* 5.0,
VMWare ESXi* 4.1 Update 1 and VMWare* ESX 4.1 Update 1.
Implication Intel
®
82579 network card cannot be recoginized under VMWare ESXi* 5.0,
VMWare ESXi* 4.1 Update 1 and VMWare* ESX 4.1 Update 1.
Status NA.
Workaround None.
29.
The boot time is 10 mins if using 4k section HDDs
Problem Using the 4K section HDDs in USB port and set it as non-boot device, it needs
10 minute to pass through. It is should be in less than one minutes.
Implication The boot up time is too long.
Status Fixed in BIOS Rev.35.
Workaround None.
11