Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor Thermal
Control %
(P1 Therm Ctrl %)
78h All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Catastrophic Error
(CATERR)
80h All
Processor
07h
Digital Discrete
03h
01 State
Asserted
Non-fatal
As and
De
Trig
Offset
M
MSID Mismatch
(MSID Mismatch)
81h All
Processor
07h
Digital Discrete
03h
01 State
Asserted
Non-fatal
As and
De
Trig
Offset
M
Processor
Population Fault
(CPU Missing)
82h All
Processor
07h
Digital Discrete
03h
01 State
Asserted
Fatal
As and
De
Trig
Offset
M
Processor VRD
Temperature
(P1 VRD Hot)
90h All
Temperature
01h
Digital Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
Trig
Offset
M
Power Supply 1 Fan
Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
Fan
04h
Threshold
01h
Analog
Power Supply 1 Fan
Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Threshold
01h
Analog
Power Supply 2 Fan
Tachometer 1
(PS2 Fan Tach 1)
A4h
Chassis-
specific
Fan
04h
Threshold
01h
Analog
Power Supply 2 Fan
Tachometer 2
(PS2 Fan Tach 2)
A5h
Chassis-
specific
Fan
04h
Threshold
01h
Analog
Processor DIMM
Aggregate Thermal
Margin
(Mem P1 Thrm
Mrgn)
B0h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Processor DIMM
Thermal Trip
(Mem P1 Thrm Trip)
C0h All
Temperature
01h
Digital Discrete
03h
01 State
Asserted
Fatal
As and
De
Trig
Offset
M X
42 Revision 2.4