Technical Product Specification

Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
IPMI Watchdog
(IPMI Watchdog)
03h All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer expired,
status only
OK As
Trig
Offset
A X
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer interrupt
Physical Security
(Physical Scrty)
04h
Chassis
Intrusion is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis
intrusion
OK
As and
De
Trig
Offset
A X
04 - LAN leash lost
FP Interrupt
(FP NMI Diag Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front panel
NMI/diagnostic
interrupt
OK As
Trig
Offset
A
SMI Timeout
(SMI Timeout)
06h All
SMI Timeout
F3h
Digital Discrete
03h
01 State
asserted
Fatal
As and
De
Trig
Offset
A
System Event Log
(System Event Log)
07h All
Event
Logging
Disabled
10h
Sensor
Specific
6Fh
02 Log area
reset/cleared
OK As
Trig
Offset
A X
System Event
(System Event)
08h All
System
Event
12h
Sensor
Specific
6Fh
04 PEF action OK As _
Trig
Offset
A X
Button Sensor
(Button)
09h All
Button/Switch
14h
Sensor
Specific
6Fh
00 Power Button
02 Reset Button
OK AS _
Trig
Offset
A X
PCH Thermal Trip
(PCH Therm Trip)
0Dh All
Temperature
01h
Digital Discrete
03h
01 State
Asserted
Fatal
As and
De
Trig
Offset
M X
Baseboard
Temperature 1
(Baseboard Temp)
20h All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Revision 2.4 39