Service Guide

46 Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN Service Guide
8. With the drive circuit-side down, position the connector end of the drive so it is
facing the rear of the drive carrier.
9. Align the holes in the drive to the holes in the drive carrier and attach it to the
carrier with the screws that were attached to the plastic retention device. See letter
“D” in Figure 25.
Figure 25. Installing Drive into Drive Carrier (R1304BTLSHBN)
10. With the black lever in the fully open position, slide the drive assembly into the
server system (see letter “E” in Figure 26). The green latch at the front of the drive
carrier must be to the right. Do not push on the black drive carrier lever until the
lever begins to close by itself.
11. When the black drive carrier lever begins to close by itself, push on it to lock the
drive assembly into place (see letter “F” in Figure 26).
AF003721
TOP
BREAK OFF TAB
BEFORE MOUTING
2.5´´ HARD DRIVE
AF003722
D
3.5´´ HDD