Technical Product Specification
Intel® Server System R1304BTSSFAN/ R1304BTLSFAN/ R1304BTLSHBN TPS Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Power Supply 1
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Power Supply 2
AC Power Input
(PS2 Power In)
55h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Power Supply 1
+12V % of
Maximum Current
Output
(PS1 Curr Out %)
58h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Power Supply 2
+12V % of
Maximum Current
Output
(PS2 Curr Out %)
59h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Power Supply 1
Temperature
(PS1 Temperature)
5Ch
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Power Supply 2
Temperature
(PS2 Temperature)
5Dh
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Processor Status
(P1 Status)
70h All
Processor
07h
Sensor
Specific
6Fh
01 – Thermal trip Fatal
As and
De
–
Trig
Offset
M X
07 – Presence
OK
Processor Thermal
Margin
(P1 Therm Margin)
74h All
Temperature
01h
Threshold
01h
– – – Analog R, T A –
Revision 2.4 41