Service Guide
Intel
®
Server System R1304BTSSFAN/R1304BTLSFAN/R1304BTLSHBN Service Guide 5
Status Green On System ready/No alarm.
Green Blink System ready, but degraded: redundancy lost
such as PS or fan failure; non-critical temp/
voltage threshold; battery failure; or predictive PS
failure.
Amber On Critical alarm: Voltage, thermal, or power fault;
CPU missing; insufficient power unit redundancy
resource offset asserted.
Amber Blink Non-Critical failure: Critical temp/voltage
threshold; VDR hot asserted; min number fans
not present or failed.
Off AC power off: System unplugged.
AC power on: System powered off and in
standby, no prior degraded\non-critical\critical
state.
Global HDD Activity Green Blink HDD access.
Off No access and no fault.
LAN 1-4 Activity/Link
(LAN 1-2 for Intel
®
Server Board
S1200BT)
Green On LAN link/no access.
Green Blink LAN access.
Off Idle.
Chassis Identification Blue On Front panel chassis ID button pressed.
Blue Blink Unit selected for identification via software.
Off No identification.
Table 2. Control Panel LED Functions
LED Color Condition What It Means