Intel® RAID Controller RT3WB080 Hardware User’s Guide Intel Order Number: G17210-001
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL(R) PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT.
Preface About this Manual Thank you for purchasing and using the Intel® RAID Controller RT3WB080. This is the primary hardware guide for the Intel® RAID Controller RT3WB080, for use with the SATA disk drives. It contains installation instructions and specifications. For details on how to configure the storage adapters, and for an overview of the software drivers, see the Intel® RAID Software User’s Guide on the Resource CD.
iv Intel® RAID Controller RT3WB080 Hardware User’s Guide
Table of Contents Preface ........................................................................................................................ iii About this Manual ................................................................................................................. iii Audience ............................................................................................................................... iii Organization .......................................................................
vi Intel® RAID Controller RT3WB080 Hardware User’s Guide
List of Figures Figure 1. Changing the Bracket................................................................................................. 8 Figure 2. Installing the Intel® RAID Controller RT3WB080 ....................................................... 8 Figure 3. Connecting Cables between the RAID Controller and Drives/Backplane ................ 10 Figure 4. Card Layout..............................................................................................................
viii Intel® RAID Controller RT3WB080 Hardware User’s Guide
List of Tables Table 1. Jumper Description ................................................................................................... 13 Table 2. Technical Specifications ............................................................................................14 Table 3. Array Performance Features .....................................................................................15 Table 4. Fault Tolerance Features ...............................................................................
x Intel® RAID Controller RT3WB080 Hardware User’s Guide
1 Overview The Intel® RAID Controller RT3WB080 is a high-performance, intelligent PCI Express* 2.0-compliant SATA III RAID controller that offers reliability, high performance, and fault-tolerant disk subsystem management. This is a RAID solution that meets the internal storage needs of workgroup, department, or enterprise systems to use cost-effective SATA or high-performance SAS media.
• Intel® Server Board S3420GP • Intel® Server System SR1690WB • Intel® Server System SR1695WB • • • • • • Intel® Server system SR2612UR Intel® Server system SR1630GP/SR1630HGP Intel® Server System SR1600UR Intel® Server System SR2600UR Intel® Server System SR2625UR Intel® Server System SR1625UR The controller supports the Serial ATA III (SATA III) protocol.
All operating systems supported by the RAID controller may not be supported by your server board. To verify compatibility, see the Tested Operating System List for your server board at http://support.intel.com/support/motherboards/server/. To make sure the RAID controller supports your operating system, refer to the Tested Hardware and Operating System List for the Intel® RAID Controller RT3WB080. Usability • • • • The card ships with both a standard and a low-profile bracket.
Redundancy and Error Handling • • • • • In-band and out-of-band SES2. Enclosure management support. Support the internal SATA Sideband signal SFF-8485 (SGPIO) interface. Drive coercion (auto-resizing to match existing disks). Auto-detection of failed drives with transparent rebuild. There must be disk activity (I/O to the drive) for a missing drive to be marked as failed. • Auto-resume on reboot of initialization or rebuild (must be enabled before virtual disk creation).
SAS/SATA Features of the LSISAS2108 Controller • Provides eight independent phys, each supporting 6Gb/s and 3Gb/s SATA data transfers per PHY. • Scalable interface that supports up to 16 physical devices and 64 virtual drives through expanders. • Supports SMP to communicate topology management information. • Supports single PHY or wide ports consisting of 2, 3, or 4 PHYs within a single quad port. • Allows addressing of multiple SATA targets through an expander if using SATA 3.
6 Intel® RAID Controller RT3WB080 Hardware User’s Guide
2 Intel® RAID Controller RT3WB080 Hardware Installation Requirements • An Intel® RAID Controller RT3WB080 with the provided cables • A host system with an available x8 or x16 PCI-Express* slot • The Resource CD, which contains drivers and documentation • SATA III or SATA II 3.0 hard drives In addition, Intel Corporation strongly recommends using an uninterruptible power supply (UPS). Installing the RAID Controller To install the RAID Controller, follow these steps: 1.
C Figure 1. Changing the Bracket 4. Install the RAID controller into an available server system x8 or x16 PCI-Express* slot (see Figure 2). To locate an appropriate slot and for instructions on installing an add-in card, see your server system documentation. IE PC r xp s* es Sl ot (3 .3 V) AF003196 Figure 2.
5. For the first four drives (ports 0 - 3), connect one 4-port combined end of an internal cable to the right connector (see letter “A” in Figure 3). If you are using more than four drives without using an expander backplane, connect the second cable to the left connector (see letter “B” in Figure 3). Connect the other end of the cables to SATA drives or to the ports on a SATA or SAS backplane (see letter “C” in Figure 3).
B A Ports 4-7 Ports 0-3 C AF003197 Figure 3. Connecting Cables between the RAID Controller and Drives/Backplane 6. Install the server system cover and connect the power cords. For instructions, see your server system documentation.
Configuring the RAID Controller To configure the RAID Controller, follow these steps: 1. Turn on the system power and listen to be sure that the SATA devices power up before or at the same time as the system. 2. During the boot, a BIOS message displays to state the keys to press to enter the Intel® RAID BIOS Console 2, such as Press to run BIOS Console 2. This message times out after several seconds. If you miss it, you need to restart the system.
12 Intel® RAID Controller RT3WB080 Hardware User’s Guide
3 Intel® RAID Controller RT3WB080 Characteristics JT2 JT12 JT13 JT10 JT1 JT4 JT7 JT6 JT9 Port 7-4 Port 3-0 JT11 JT8 JT3 AF003198 Figure 4. Card Layout Table 1. Jumper Description Jumper Description Type Comments JT1 Dirty Cache LED Header 2-pin connector For connection to enclosure LED. When lit, it indicates the data in the cache has not been written to disk. JT2 Drive Activity LED Header 2-pin connector LED signal for drive activity.
Jumper Description Type Comments JT11 Keyed I2C Connector 3-pin keyed connector Out-of-band enclosure management (SES2) JT12 Individual Drive Fault LED header 8 x 2 header Indicates drive faults. There is one LED per port. When lit, each LED indicates the corresponding drive has failed or is in the Unconfigured-Bad state. The LEDs function in a direct-attach configuration (there are no SAS expanders). Direct attach is defined as a maximum of one drive connected directly to each port.
Intel® RAID Controller RT3WB080 Specification Enclosure support Assumes one SEP per enclosure Array Performance Features Table 3. Array Performance Features Intel® RAID Controller RT3WB080 Specification Host data transfer rate Up to 5.0 Gb/s per PCI Express* lane Drive data transfer rate Up to 6.0 Gb/s per phy Maximum scatter/gather 80 elements Maximum size of I/O requests 6.
Fault Tolerance Table 4. Fault Tolerance Features Intel® RAID Controller RT3WB080 Specification Self Monitoring Analysis and Reporting Technology (SMART) support • • Detects up to 70% of predictable disk drive failures Monitors the internal performance of all motors, heads, and drive electronics. Optional Battery Backup • • Intel® RAID Smart Battery AXXRSBBU7 cache backup Up to 48 hours of data retention, “Gas Gauge".
Electrical Characteristics Table 5. Electrical Characteristics Characteristic Values PCI +12 V 1.0A PCI +3.3 Aux 30 mA PCI +3.
18 Intel® RAID Controller RT3WB080 Hardware User’s Guide
Appendix A: Drive Roaming and Drive Migration Install Drive Roaming Drive roaming occurs when the hard drives are changed to different ports on the same controller. When the drives are placed on different ports, the controller detects the RAID configuration from the configuration data on the drives. Note: If you move a drive that is currently being rebuilt, the rebuild operation will restart, not resume. To use drive roaming, follow these steps: 1.
Drive Migration Drive migration moves a configured set of hard drives from one controller to another. The drives must remain on the same port and be reinstalled in the same order as in the original configuration. The controller to which you migrate the drives cannot have an existing configuration. Note: Only complete configurations can be migrated; individual virtual disks cannot be migrated. Drive roaming and drive migration cannot be supported at the same time. To migrate drives, follow these steps: 1.
Appendix B: Installation/Assembly Safety Instructions As you use your computer system, observe these safety guidelines: • Do not operate your computer system with any cover(s) (such as computer covers, bezels, filler brackets, and front panel inserts) removed. • To help avoid damaging your computer, be sure the voltage selection switch on the power supply is set to match the alternating current (AC) power available at your location.
Additional safety guidelines: • When you disconnect a cable, pull on its connector or on its strain-relief loop, not on the cable itself. Some cables have a connector with locking tabs; if you are disconnecting this type of cable, press in on the locking tabs before disconnect the cable. As you pull connectors apart, keep them evenly aligned to avoid bending any connector pins. Also, before you connect a cable, make sure both connectors are correctly oriented and aligned.
English Read all caution and safety statements in this document before performing any of the instructions. See also Intel® Server Boards and Server Chassis Safety Information on the Resource CD and/or at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. The power button on the system does not turn off system AC power. To remove AC power from the system, you must unplug each AC power cord from the wall outlet or power supply.
A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges on some board and chassis parts. Contact should be made with care. Consider wearing protective gloves. Deutsch Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und -Servergehäusen auf der Ressourcen-CD oder unter http://support.intel.
SICHERHEITSMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten Sie folgende Schritte beachten: 1. Schalten Sie alle an Ihr System angeschlossenen Peripheriegeräte aus. 2. Schalten Sie das System mit dem Hauptschalter aus. 3. Ziehen Sie den Stromanschlußstecker Ihres Systems aus der Steckdose. 4. Auf der Rückseite des Systems beschriften und ziehen Sie alle Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5.
Notez que le commutateur CC de mise sous tension/hors tension du panneau avant n'éteint pas l'alimentation CA du système. Pour mettre le système hors tension, vous devez débrancher chaque câble d'alimentation de sa prise. C'est le câble d'alimentation qui est considéré comme le moyen de se déconnecter du CA. La prise à laquelle le système est branché doit se situer à proximité de l'équipement et être facilement accessible.
Le microprocesseur et le dissipateur de chaleur peuvent être chauds si le système a été sous tension. Faites également attention aux broches aiguës des cartes et aux bords tranchants du capot. Nous vous recommandons l'usage de gants de protection. Español Lea todas las declaraciones de seguridad y precaucion de este documento antes de realizar cualquiera de las instrucciones. Vea Intel® Server Boards and Server Chassis Safety Information en el CD Resource y/o en http://support.intel.
Para obtener un enfriamiento y un flujo de aire adecuados, reinstale siempre las tapas del chasis antes de poner en marcha el sistema. Si pone en funcionamiento el sistema sin las tapas bien colocadas puede dañar los componentes del sistema. Para instalar las tapas: 1. Asegúrese primero de no haber dejado herramientas o componentes sueltos dentro del sistema. 2. Compruebe que los cables, las placas adicionales y otros componentes se hayan instalado correctamente. 3.
PASSI DI SICUREZZA: Qualora si rimuovano le coperture del telaio per accedere all'interno del sistema, seguire i seguenti passi: 1. Spegnere tutti i dispositivi periferici collegati al sistema. 2. Spegnere il sistema, usando il pulsante spento/acceso dell'interruttore del sistema. 3. Togliere tutte le spine dei cavi del sistema dalle prese elettriche. 4. Identificare e sconnettere tutti i cavi attaccati ai collegamenti I/O od alle prese installate sul retro del sistema. 5.
30 Intel® RAID Controller RT3WB080 Hardware User’s Guide
Appendix C: Regulatory and Certification Information This RAID Controller Card complies with the following safety and electromagnetic compatibility (EMC) regulations.
• BSMI DOC Mark (Taiwan) • ACS C-Tick Mark (Australia) Regulatory Compliance NRTL Certification Marking Country Marking USA/Canada OR CE Mark Europe FCC Marking (Class A) USA This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Electromagnetic Compatibility Notices FCC Verification Statement (USA) : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Intel Corporation 5200 N.E.
and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance.