User Guide
40 Intel® Integrated RAID Solution User Guide
Program Return Value
0x00 – SUCCESS: Command completed successfully.
0x01 – FAILURE: Bad command-line arguments or operational failure.
0x02 – ADAPTER_NOT_FOUND: Cannot find specified adapter.
DELETEVOLUME
The DELETEVOLUME command deletes a specific RAID 0, RAID 1, RAID 10 or RAID 1E
volume and the associated hot spare drives on the specified controller. The hot spare is
deleted only if it is inappropriate for any of the remaining volumes. No other controller
configuration parameters are changed. Use the
STATUS command or the DISPLAY
command to determine the volumeID of the volume you want to delete.
Command Line
sas3ircu <controller_#> deletevolume <volumeID> [noprompt]
Parameters
• <controller_#> – The index of the controller with the volume or volumes that
you want to delete.
• <volumeID> – The volumeID of the specific IR volume that you want to delete.
• [noprompt] – This optional parameter prevents warnings and prompts from
appearing while the command is running.
Program Return Value
0x00 – SUCCESS: Command completed successfully.
0x01 – FAILURE: Bad command-line arguments or operational failure.
0x02 – ADAPTER_NOT_FOUND: Cannot find specified adapter.
DISPLAY
The DISPLAY command displays information about Intel SAS-3 controller
configurations, including controller type, firmware version, BIOS version, volume
information, physical drive information, and enclosure. See the following sample output
example.
The physical device information section displays the duplicate device of a dual-port SAS
drive.