Intel RAID Controllers Alert Code Decoding White Paper

IntelĀ® RAID Controllers: SAS Software Stack Appendix A
Revision 1.0
25
27h/04h T R PERSISTENT WRITE PROTECT
27h/05h T R PERMANENT WRITE PROTECT
27h/06h R CONDITIONAL WRITE PROTECT
28h/00h DTLPWROMAEBKVF NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED
28h/01h DT WROM B IMPORT OR EXPORT ELEMENT ACCESSED
28h/02h R FORMAT-LAYER MAY HAVE CHANGED
29h/00h DTLPWROMAEBKVF POWER ON, RESET, OR BUS DEVICE RESET OCCURRED
29h/01h DTLPWROMAEBKVF POWER ON OCCURRED
29h/02h DTLPWROMAEBKVF SCSI BUS RESET OCCURRED
29h/03h DTLPWROMAEBKVF BUS DEVICE RESET FUNCTION OCCURRED
29h/04h DTLPWROMAEBKVF DEVICE INTERNAL RESET
29h/05h DTLPWROMAEBKVF TRANSCEIVER MODE CHANGED TO SINGLE-ENDED
29h/06h DTLPWROMAEBKVF TRANSCEIVER MODE CHANGED TO LVD
29h/07h DTLPWROMAEBKVF I_T NEXUS LOSS OCCURRED
2Ah/00h DTL WROMAEBKVF PARAMETERS CHANGED
2Ah/01h DTL WROMAEBKVF MODE PARAMETERS CHANGED
2Ah/02h DTL WROMAE K LOG PARAMETERS CHANGED
2Ah/03h DTLPWROMAE K RESERVATIONS PREEMPTED
2Ah/04h DTLPWROMAE RESERVATIONS RELEASED
2Ah/05h DTLPWROMAE REGISTRATIONS PREEMPTED
2Ah/06h DTLPWROMAEBKVF ASYMMETRIC ACCESS STATE CHANGED
2Ah/07h DTLPWROMAEBKVF IMPLICIT ASYMMETRIC ACCESS STATE TRANSITION FAILED
2Ah/08h DT WROMAEBKVF PRIORITY CHANGED
2Ah/09h D CAPACITY DATA HAS CHANGED
2Ah/10h DT M E V TIMESTAMP CHANGED
2Ah/11h T DATA ENCRYPTION PARAMETERS CHANGED BY ANOTHER I_T
NEXUS
2Ah/12h T DATA ENCRYPTION PARAMETERS CHANGED BY VENDOR SPECIFIC
EVENT
2Ah/13h T DATA ENCRYPTION KEY INSTANCE COUNTER HAS CHANGED
2Bh/00h DTLPWRO K COPY CANNOT EXECUTE SINCE HOST CANNOT DISCONNECT
2Ch/00h DTLPWROMAEBKVF COMMAND SEQUENCE ERROR
2Ch/01h TOO MANY WINDOWS SPECIFIED
2Ch/02h INVALID COMBINATION OF WINDOWS SPECIFIED
2Ch/03h R CURRENT PROGRAM AREA IS NOT EMPTY
2Ch/04h R CURRENT PROGRAM AREA IS EMPTY
2Ch/05h B ILLEGAL POWER CONDITION REQUEST
2Ch/06h R PERSISTENT PREVENT CONFLICT
2Ch/07h DTLPWROMAEBKVF PREVIOUS BUSY STATUS
2Ch/08h DTLPWROMAEBKVF PREVIOUS TASK SET FULL STATUS
2Ch/09h DTLPWROM EBKVF PREVIOUS RESERVATION CONFLICT STATUS
2Ch/0Ah F PARTITION OR COLLECTION CONTAINS USER OBJECTS
2Ch/0Bh T NOT RESERVED
2Dh/00h T OVERWRITE ERROR ON UPDATE IN PLACE
2Eh/00h R INSUFFICIENT TIME FOR OPERATION
2Fh/00h DTLPWROMAEBKVF COMMANDS CLEARED BY ANOTHER INITIATOR
2Fh/01h D COMMANDS CLEARED BY POWER LOSS NOTIFICATION
2Fh/02h DTLPWROMAEBKVF COMMANDS CLEARED BY DEVICE SERVER
30h/00h DT WROM BK INCOMPATIBLE MEDIUM INSTALLED
30h/01h DT WRO BK CANNOT READ MEDIUM - UNKNOWN FORMAT
30h/02h DT WRO BK CANNOT READ MEDIUM - INCOMPATIBLE FORMAT
30h/03h DT R K CLEANING CARTRIDGE INSTALLED
30h/04h DT WRO BK CANNOT WRITE MEDIUM - UNKNOWN FORMAT
30h/05h DT WRO BK CANNOT WRITE MEDIUM - INCOMPATIBLE FORMAT
30h/06h DT WRO B CANNOT FORMAT MEDIUM - INCOMPATIBLE MEDIUM
30h/07h DTL WROMAEBKVF CLEANING FAILURE
30h/08h R CANNOT WRITE - APPLICATION CODE MISMATCH
30h/09h R CURRENT SESSION NOT FIXATED FOR APPEND
30h/0Ah DT WROMAEBK CLEANING REQUEST REJECTED
30h/0Ch T WORM MEDIUM - OVERWRITE ATTEMPTED