User Guide
Intel® Integrated RAID Solution User Guide 47
CONSTCHK
The CONSTCHK command requests the Integrated RAID firmware to start a consistency
check operation on the specified volume.
Command Line
sas3ircu <controller_#> constchk <volumeId> [noprompt]
Parameters
• <controller_#> – The index of the controller on which the consistency check
operation runs.
• <volumeId> – The volume ID of an Integrated RAID volume, as listed in the
DISPLAY command, on which the consistency check operation runs.
• [noprompt] – This optional parameter prevents warnings and prompts from
appearing while the command is running.
Program Return Value
0x00 – SUCCESS: Command completed successfully.
0x01 – FAILURE: Bad command-line arguments or operational failure.
0x02 – ADAPTER_NOT_FOUND: Cannot find specified adapter.
ACTIVATE
The ACTIVATE command activates an inactive Integrated RAID volume.
Command Line
sas3ircu <controller_#> activate <volumeId>
Parameters
• <controller_#> – The index of the controller with the volume that requires
activation.
• <volumeId> – The volume ID of an Integrated RAID volume currently in the
Inactive state.
Program Return Value
0x00 – SUCCESS: Command completed successfully.