User Guide

Intel® Integrated RAID Solution User Guide 45
STATUS
The STATUS command displays the current status of any existing Integrated RAID
volumes and the status of any operation that is currently in progress on the selected
controller. If no operation is in progress, SAS3IRCU prints a message indicating this
condition before it exits.
Command Line
sas3ircu <controller_#> status
Parameters
<controller_#> – The index of the controller with the volumes whose status you
want to display.
Program Return Value
0x00 – SUCCESS: Command completed successfully.
0x01 – FAILURE: Bad command-line arguments or operational failure.
0x02 – ADAPTER_NOT_FOUND: Cannot find specified adapter.
Sample Output
Following is an example of the information that the STATUS command returns. In this
example, a background initialization is in progress on IR Volume 1, and no operation is in
progress on IR Volume 2.
Background command progress status for controller 0...
IR Volume 1
Volume ID : 322
PI Supported : Yes
PI Enabled : Yes
Current operation : Background Init
Volume status : Enabled
Volume state : Optimal
Volume wwid : 054f59a844a86682
Physical disk I/Os : Not quiesced
Volume size (in sectors) : 285155328
Number of remaining sectors : 283997632
Percentage complete : 0.41%
IR Volume 2
Volume ID : 323
Current operation : None
Volume status : Enabled
Volume state : Optimal