User Guide

Intel® Integrated RAID Solution User Guide 41
Command Line
sas3ircu <controller_#> display [filename]
Parameters
<controller_#> – The index of the controller for which you want to display
information.
[filename] – An optional valid filename to store the command output to a file.
Program Return Value
0x00 – SUCCESS: Command completed successfully.
0x01 – FAILURE: Bad command-line arguments or operational failure.
0x02 – ADAPTER_NOT_FOUND: Cannot find specified adapter.
Sample Output
Following is a sample of the information that the DISPLAY command returns.
Read configuration has been initiated for controller 0
----------------------------------------------------------------
Controller information
----------------------------------------------------------------
Controller type : SAS3008
PI Supports : Yes
PI Mixing : Enabled
BIOS version : 7.00.02.00
Firmware version : 00.250.19.0
Channel description : 1 Serial Attached SCSI
Initiator ID : 112
Maximum physical devices : 62
Concurrent commands supported : 266
Slot : 3
Segment : 0
Bus : 64
Device : 1
Function : 0
RAID Support : Yes
----------------------------------------------------------------
IR Volume information
----------------------------------------------------------------
IR volume 1
Volume ID : 286
PI Supported : Yes
PI Enabled : Yes