Hardware User Guide

45 12Gb/s Intel® RAID Controllers User Guide
Table 17. Power Supply for the Intel
®
RAID Controller RS3SC008
Operating and Nonoperating Conditions for the Intel
®
RAID Controller
RS3SC008
For the Intel
®
RAID Controller RS3SC008, the operating (thermal and atmospheric)
conditions are as follows:
Relative humidity range is 20 percent to 80 percent noncondensing.
Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the
LSISAS3108 processor above the maximum ambient temperature.
Temperature range: 10°C to +55°C
The parameters for the nonoperating (such as storage and transit) environment for these
controllers are as follows:
Relative humidity range is 5 percent to 90 percent noncondensing.
Temperature range: –40°C to +70°C
Power Supply Requirements for the Intel
®
RAID Module RMS3CC080
All power is supplied to the Intel
®
RAID Module RMS3CC080 through the PCIe 3.3V
rails and the 12V rail. On-board switching regulator circuitry operating from the 3.3V
rails and the 12V rail provides the necessary voltages. The following states determine the
typical current consumption of the controller:
State 1: While sitting idle at the DOS prompt
State 2: During a drive stress test
The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9
percent (from PCI edge connector only). The following table lists the power supply for the
RAID controllers for these two states at the different voltages.
PCI Edge Connector State 1 State 2
3.3V supply 800mA 880mA
+12V supply 1000mA 1220mA
3.3V auxiliary supply 20mA 20mA