Enclosure Management Cabling for Rack-Optimized Systems

Aug 2010
1
Note: Before cabling, please refer to the respective RAID module or RAID controller Tested
Hardware and Operating System lists, in order to confirm their compatible Intel
®
Server Boards
or Systems.
When using a rack-optimized system with passive backplane / midplane and an add-in RAID
card, you must install an additional 3-pin SES cable, or 4-pinSGPIO cable between the RAID
card and the backplane or midplane to enable fault LED control. The cable is included with your
integrated system or backplane / midplane kit.
The following connectors should be used on the add-in RAID controllers:
Intel® RAID Controller Connector
RS2SG244, RS2WG160
J1C1, white
RS2BL080, RS2BL080DE,
RS2BL080SNGL, RS2BL040
J11, white
RS2MB044 J1A4, white
RS2PI008, RS2PI008DE None.
RS2WC080, RS2WC040 J7, white
RMS2MH080 J4A1, white
RMS2AF080, RMS2LL080
J1A1, 3-pin, SES, white;
J1A2/J1B2, 4-pin, SGPIO, black/blue
RMS2AF040, RMS2LL040
J1A1, 3-pin, SES, white;
J1A2, 4-pin, SGPIO, black
SRCSATAWB, SRCSASRB
J6, white
Note: RAID FW 420 or higher is required.
SRCSASJV
J2, white
Note: RAID FW 312 or higher is required.
SRCSASBB8I, SRCSASLS4I J7, white
SATA Embedded RAID (ESB2) No additional cable needed with rack chassis.
SAS Embedded RAID (LSI* 1064e) No additional cable needed with rack chassis.
SRCS16
Connector: 4-pin J6, see picture
Note: RAID firmware ver. 713S or higher and HSC
FW 2.05 or higher are required
SRCS28X
J13, 3-pin, white
Note: HSC FW 2.05 or higher is required.
SRCSAS18E J18, 3-pin, white
SRCSAS144E
Enclosure management not supported with passive
backplanes/midplanes. Do not connect SES cable.
Note: Below cable is SFF8087 to Four-port Internal Cable with one SGPIO Connector. This