16 Intel® RAID Controller RS2VB080/RS2VB040 Hardware User’s Guide
Fault Tolerance
Table 4. Fault Tolerance Features
Maximum queue tags per
drive
As many as the drive can accept
Stripe sizes 8, 16, 32, 64, 128, 256, 512, or 1024 KB
Maximum concurrent
commands
1024-16
Support for multiple initiators Ye s
Performance Native command queuing
Flexibility Drive migration
RAID level migration
Drive Roaming
Online Capacity Expansion - without reboot
Background services Rebuild
Consistency Check
Migration
OCE
Patrol Read
Cache options Write-back or Write-through
Read Ahead, Adaptive Read Ahead, or Non-Read Ahead
Cache I/O or Direct I/O
Specification Intel
®
RAID Controller RS2VB080/RS2VB040
Specification Intel® RAID Controller RS2VB080/RS2VB040
Self Monitoring Analysis and
Reporting Technology (SMART)
support
Detects up to 70% of predictable disk drive failures
Monitors the internal performance of all motors,
heads, and drive electronics.
Optional Battery Backup SuperCap module shipped with the card
Up to 72 hours of data retention, “Gas Gauge".
Drive Replacement Auto detection of failure.
Hot plug.
Hot swap.
Drive Rebuild Using Hot Spares Automatic at fail.
Dedicated per array.
Global for any array.
Auto-resume of initialization or rebuild on reboot.