technical documents for more details. RAID controllers that are shipped with this cable can
connect the cable’s SGPIO connector to the SGPIO header on the backplanes or midplanes
listed in this document, so as to enable fault LED control.
The following connectors should be used on the backplanes/midplanes:
Intel® Server System/Chassis Connector
SR1600UR with passive backplane HBA CONN on backplane, 3-pin, white
SR1600URHS* (need to work together with the
passive backplane ASR1500PASBP which has to
be ordered separately as an accessory.)
HBA CONN on backplane, 3-pin, white
SR1625UR HBA CONN on backplane, 3-pin, white
SR2600URBRP HBA CONN on backplane, 3-pin, white
SR2600URSATA HBA CONN on backplane, 3-pin, white
SR2625URBRP HBA CONN on backplane, 3-pin, white
SR1690WB
HBA CONN on backplane, 3-pin, white; Or SGPIO
header, 4-pin, black
SR1695WB / SR1695GPRX
HBA CONN on backplane, 3-pin, white; Or SGPIO
header, 4-pin, black
SR1630HGP
SGPIO header, 4-pin, black
SR1500AL / SR1500 with passive backplane HBA CONN on backplane, 3-pin, white
SR1550AL / SR1550 with passive midplane HBA CONN on midplane, 3-pin, white
SR2500ALBRP / SR2500 with passive midplane HBA CONN on midplane, 3-pin, white
SR1560SF with passive backplane HBA CONN on backplane, 3-pin, white
SR2520SAX (passive backplane) Add-in RAID cards not supported. Only the onboard
controller can be used.
IMPORTANT: No cable for fault LED control is needed if using the onboard SAS or SATA RAID
controller. No cable for fault LED control is needed if using an active backplane / midplane. In
these configurations, connecting 3-pin I2C cable or 4-pin SGPIO cable to backplane / midplane
may cause unexpected system behavior.