Intel RAID Performance 12Gb/s SAS RAID Controllers
Intel®RAIDPerformance12Gb/sSASRAIDControllersWhitePaper
Figure4IntelIntegratedRAIDModuleRMS3CC08012Gb/sSASSSD,TransactionalWorkloads
TheIntel12Gb/sSASRAIDcontrollerexhibitsincrediblyhighperformance,easilyachievingmorethan
500,0008-KBrandomreads-nearly4,000MBps.Thistranslatestomorethan100,000database
operationsforatypicalRAID10conguration,andevenamorecapacity-optimizedRAID5conguration
canstillachieveupwardsof70,000databasetypeIOPs.
2.3 Common Enterprise Applications
Workstation workloads represent primarily single tenancy operating systems running multiple
applicationsthatpredominatelyhandlerandomreadrequests,withamixofsequentialreadsandwrites.
Lowresponsetimesandeectivecachingstrategiesareessentialforworkstationusers.
Webserverworkloadstypicallyservicemultiple,primarilyrandomsimultaneousrequests.Text,images,
video,andaudioarecommonlyfeaturedlesservedbywebservers,withahighskewtowardsthemost
popular web pages. Low response times are critical to support fast page loads and ensure customer
satisfaction.
Operating system drive workloads represent the I/O activity of an operating system drive. This workload
isdenedasapseudorandom70:30mixofreadsandwritescombinedwithsmallsequentialI/Osthat
simulatelogging.Operatingsystemsmustmanagesystemcache,metadataandapplicationcodeand
eectivecachingoffrequentlyaccesseddata,whilemaintainingdataintegrity.Theabilitytohandle
numerousoutstandingrequestsisabsolutelyessential.Withtheextensiveuseofvirtualization
anddistributedletechnologies,optimalOSperformanceismoreimportantthanever.
Fileserverworkloadsarecharacterizedbyalargenumberofusersrequestingaccesstostructured
referencedataandles.Whilelesystemsandaccesspatternscanvarysignicantly,wemeasure80:20
randomreadandwriteworkloadwiththemajorityofrequestsizesranging,bimodallybalanced,around4
KBand64KB.
Email server workloads typically service multiple simultaneous requests to transport or store email. Many
email servers use databases or database-like structures to manage and store user data. Because of the
variationsinemailserverapplications,twocommontypesofemailserversweresimulatedintesting:
1.8KB50%mixofrandomreadsandwrites
2.32KB65%mixofrandomreadsandwrites
Thefollowingguresshowthecommonenterpriseapplicationperformancetestingresultsat6Gb/sSAS
and12Gb/sSAS.