Hardware User's Guide

14 Intel® RAID Controller RS2BL040 Hardware User’s Guide
Fault Tolerance
Table 4. Fault Tolerance Features
Specification Intel
®
RAID Controller RS2BL040
Self Monitoring Analysis and
Reporting Technology (SMART)
support
Detects up to 70% of predictable disk drive failures
Monitors the internal performance of all motors,
heads, and drive electronics.
Optional Battery Backup Intel
®
RAID Smart Battery AXXRSBBU7 cache
backup
Up to 72 hours of data retention, “Gas Gauge".
Drive Replacement Auto detection of failure
Hot plug
Hot swap
Drive Rebuild Using Hot Spares Automatic at fail
Dedicated per array
Global for any array
Auto-resume of initialization or rebuild on reboot
Error Checking and Indication Parity generation and checking, automatic
consistency checking
Patrol reads
Activity and fault LEDs, alarm
Multiple retries
Logs in NVRAM, event log, CIM, Smart, Intel
®
RAID
Web Console 2