Hardware User's Guide

22 Intel® RAID Controller RS25SB008 Hardware User’s Guide
Fault Tolerance
Table 9. Fault Tolerance Features
Maximum size of I/O requests 6.4 Mbytes in 64 Kbyte stripes
Maximum queue tags per
drive
As many as the dri
ve can accept
Stripe sizes 8, 16, 32, 64, 128, 256, 512, or 1024 KB
Maximum concurrent
commands
255
Support for multiple initiators Ye s
Performance Native command queuing
Flexibility
Drive migration
RAID level migration
Drive Roaming
Online Capacity Expansion - without reboot
Background services
Rebuild
Consistency Check
Migration
OCE
Patrol Read
Cache options
Write-back or Write-through
Read Ahead
Adaptive Read Ahead
Non Read Ahead
Cache I/O or Direct I/O
Disk Cache
Specification Intel
®
RAID Controller RS25SB008
Specification Intel
®
RAID Controller RS25SB008
Self Monitoring Analysis and
Reporting Technology (SMART)
sup
port
Detects up to 70% of predictable disk drive failures
Monitors the internal performance of all motors, heads,
and drive electronics.
Backup Unit
Super Cap 2 cache backup unit
Up to 48 hours of data retention, longer life time than
battery backup unit
Drive Replacement
Auto detection of failure
Hot-plug
Hot-swap