Hardware User's Guide
Intel® RAID Controller RS25SB008 Hardware User’s Guide 15
RAID transactions. Cache mode selection takes immediate effect while the server is
online and is available on a per virtual drive basis. The ROC memory controller provides
single-bit ECC error correction with multi-bit detection support.
The Intel
®
RAID Controller RS25SB008 supports Super Cap 2 module.
Super Cap 2 backup unit is an industrial new technology to dramatically enlarge the life
time of the backup unit. There is no need to replace the backup unit with a new one every
year. (While traditional battery backup unit is required to be replaced after used for one
year, or when 500 learn cycles are reached.) In the Intel
®
RAID Controller RS25SB080
packaging kit, there is also a mounting bracket for holding the Super Cap 2 backup
unit.See below figure for reference only. Actual shape of the product may vary from
the figure.
Figure 6. Super Cap 2 Backup Unit with Bracket
Note: I
ntel Corporation strongly recommends using an uninterruptible power supply (UPS).
Diagnostic Components
Audible Alarm
The audible alarm beeps when a drive fails and also during a rebuild. The drive failure
alarm beeps are:
•
Degraded array: Short tone, one second on, one second off.
•
Failed array: Long tone, three seconds on, one second off.
•
Hot spare commissioned: Short tone, one second on, three seconds off.
A