26 Intel® RAID Controller RS25NB008 Hardware User’s Guide
RAID Physical Drive Status
Table 11. RAID Physical Drive Status
RAID Virtual Drive Status
Table 12. RAID Virtual Drive Status
Drive State Code Description
Unconfigured Good Unconfigured Good The drive is functioning normally, but is not part of
a configured virtual drive and is not a hot spare.
Online ONLN The drive is online, is part of a configured
virtual drive, and is functioning normally.
Hot Spare HOTSP A physical drive that is configured as a hot spare.
Failed FAILED A physical drive that was originally configured as
Online or Hot Spare, but on which the firmware
detects an unrecoverable error.
Rebuilding REBUILD A physical drive to which data is being written to
restore full redundancy for a virtual drive.
Unconfigured Bad Unconfigured Bad A physical drive on which the firmware detects an
unrecoverable error; the physical drive was Uncon
-
figured Good or the physical drive could not be
initialized.
Missing Missing A physical drive that was online, but which has been
removed from its location.
Offline Offline A physical drive that is part of a virtual drive but
which has invalid data as far as the RAID configura
-
tion is concerned.
None None A physical drive with an unsupported flag set. An
Unconfigured Good or Offline physical drive that has
completed the 'prepare for removal' operation.
Drive State Code Description
Optimal Optimal The drive operating system is good. All config-
ured drives are online.
Degraded Degraded The drive operating condition is not optimal
because one of the configured drives has failed
or is offline.
Offline Offline The drive is not available to the operating system
and is unusable.