47 12Gb/s Intel® RAID Controllers User Guide
Operating and Nonoperating Conditions for the Intel
®
RAID Module
RMS3HC080
For the Intel
®
RAID Module RMS3HC080, the operating (thermal and atmospheric)
conditions are as follows:
• Relative humidity range is 5 percent to 90 percent noncondensing.
• Airflow must be at least 75 linear feet per minute (LFPM) to avoid operating the
LSISAS3008 processor above the maximum ambient temperature.
• Temperature range: 0°C to +55°C
The parameters for the nonoperating (such as storage and transit) environment for these
controllers are as follows:
• Relative humidity range is 5 percent to 90 percent noncondensing.
• Temperature range: –45°C to +105°C
Safety Characteristics
All 12Gb/s Intel
®
RAID Controllers meet or exceed the requirements of UL flammability
rating 94 V0. Each bare board is also marked with the supplier name or trademark, type,
and UL flammability rating. For the boards installed in a PCI Express bus slot, all voltages