Hardware User Guide

12Gb/s Intel® RAID Controllers User Guide 46
Table 18. Power Supply for the Intel
®
RAID Module RMS3CC080 (TBD)
Operating and Nonoperating Conditions for the IIntel
®
RAID Module
RMS3CC080
For the Intel
®
RAID Module RMS3CC080, the operating (thermal and atmospheric)
conditions are as follows:
Relative humidity range is 20 percent to 80 percent noncondensing.
Airflow must be at least 200 linear feet per minute (LFPM) to avoid operating the
LSISAS3108 processor above the maximum ambient temperature.
Temperature range: +10°C to +55°C without battery backup unit
Temperature range: +10°C to +45°C with battery backup unit
The parameters for the nonoperating (such as storage and transit) environment for these
controllers are as follows:
Relative humidity range is 5 percent to 90 percent noncondensing.
Temperature range: –40°C to +70°C without battery backup unit
Temperature range: 0°C to +45°C with battery backup unit
Power Supply Requirements for the Intel
®
RAID Module RMS3HC080
All power is supplied to the Intel
®
RAID Module RMS3HC080 through the PCIe 3.3V
rails and the 12V rail. On-board switching regulator circuitry operating from the 12V rail
provides the necessary voltages.
The supply voltages are 12V ± 8 percent (from PCI edge connector only) and 3.3V ± 9
percent (from PCI edge connector only). The following table lists the power for the RAID
controllers at peak and normal status.
Table 19. Power Supply for the Intel
®
RAID Module RMS3HC080 (TBD)
PCI Edge Connector State 1 State 2
3.3V supply
+12V supply
3.3V auxiliary supply
Total Power
Power Mode Power Mode Description DC Power (Watts)
Peak (on-max) Maximum
On-Normal/Typical Typical