Intel® Integrated RAID Module RMS25PB0x0 and RMS25CB0x0 Hardware User’s Guide 31
Fault Tolerance
Table 9. Fault Tolerance Features
Maximum concurrent
commands
255
Support for multiple initiators Ye s
Performance Native command queuing
Flexibility Drive migration
RAID level migration
Drive Roaming
Online Capacity Expansion - without reboot
Background services Rebuild
Consistency Check
Migration
OCE
Patrol Read
Cache options Write-back or Write-through
Read Ahead
Adaptive Read Ahead
Non Read Ahead
Cache I/O or Direct I/O
Disk Cache
Specification
Intel
®
Integrated RAID Module RMS25PB080,
RMS25PB040, RMS25CB080 and RMS25CB040
Specification
Intel
®
Integrated RAID Module RMS25PB080,
RMS25PB040, RMS25CB080 and RMS25CB040
Self Monitoring Analysis and
Reporting Technology (SMART)
support
Detects up to 70% of predictable disk drive failures
Monitors the internal performance of all motors, heads,
and drive electronics
Optional Cache Memory Backup Intel
®
RAID Smart Battery AXXRSBBU9 cache backup
up to 48 hours of data retention, ‘Gas Gauge’
Intel
®
RAID Maintenance Free Backup Unit
AXXRMFBU2
Drive Replacement Auto detection of failure
Hot-plug
Hot-swap
Drive Rebuild Using Hot Spares Automatic at fail
Dedicated per Array
Global for any array
Auto-resume of initialization or rebuild on reboot