Hardware user guide
8 Intel® Integrated RAID Module RMS25KB0x0 and RMS25JB0x0 Hardware User’s Guide
Installing the Intel
®
Integrated RAID Module
RMS25JB0x0
To install the RAID module, follow these steps:
1. Turn off the power to the system, all drive
s, enclosures, and system components.
Remove the power cord(s).
2. Remove the server cover. For instructions,
see your server system documentation.
3. Insert the three barrel standoffs into the matchin
g holes in the server board. To
locate the matching module card slot on your server board, see your server board
documentation. The Intel
®
Server Board S2600IP is shown for illustrative purpose.
Actual standoff hole locations could be different (see Figure 1).
Figure 4. Installing the Barrel Standoff
4. Attach the RAID to the matching server boa
rd connector, and press the module card
firmly to engage the barrel standoffs installed in step 3 (see Figure 3). Press down
gently but firmly to ensure that the card is properly se
ated in the connectors, and
then insert the four pin standoffs into the barrel standoffs respectively. The Intel
®
RAID Module RMS25KB080 is shown for illustrative purpose (see Figure 5).
AF004406