Intel® Integrated RAID Module RMS25KB0x0 and RMS25JB0x0 Hardware User’s Guide 3
The operating systems supported may not be supported by your server board. See the
Tested operating system list for your server board at
http://www.intel.com
.
To make sure the RAID module supports your operating system, see also the Tested
Hardware and Operating System List for the Intel
®
Integrated RAID Module
RMS25KB080, RMS25KB040, RMS25JB080 and RMS25JB040.
Usability
The the Intel
®
Integrated RAID Module RMS25KB080 and RMS25KB040 ship
with both a standard and a low-profile bracket.
Small, thin cabling with up to 6.0 Gb/s serial, point-to-point data transfer rates.
Support for non-disk devices and mixed capacity drives.
Support for RAID levels 0, 1, 1E, and 10.
Dedicated or global hot spare with auto rebuild if an array drive fails.
Fixed RAID strip size of 64 KB.
Advanced array configuration and management utilities that provide drive roaming.
Allows for staggered spin-up, hot-plug, and lower power consumption.
Redundancy and Error Handling
Sideband SGPIO Enclosure management support.
Activity and fault indicators per drive.
Auto-detection of failed drives with transparent rebuild.
Commands are retried up to four times.
SMART technology predicts failures of drives and electronic components for drives
in IR mode.
Firmware provides best effort to recognize an error and recover from it if possible.
Failures are logged from controller and drive firmware.
Failures are logged in Intel
®
RAID Web Console 2, CIM, and LEDs.