Enclosure Management Cabling for Intel C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures
Board
Drive
Numbe
r &
Type
Fixed or
hot-
swap
Types of
Drives
Supported
2
Drive kit required
Expander
required
Required Cabling if
using On-board
SATA Capable
Controller
Required Cabling if
using On-board SAS
Controller on
S2600CW2S or
S2600CWTS
Required Cabling if
using 12Gb/s RAID
Controller
1
Required Cabling if
using 6Gb/s RAID
Controller
1
S2600CW
16x2.5”
Hot
Swap
SATA +
SAS
2X
FUP8X25S3HSDK
No
expander
(use
onboard
SATA and
SAS
controllers,
or use two
8 port
HBAs. You
will not be
able to
create a
single array
across all
drives)
2x AXXCBL380HDHD
2x
AXXCBL650HDHD
2x
AXXCBL650HDMS
2X
FUP8X25S3HSDK
1x
RES3TV36
0
N/A
Controller to
Expander: 1x
AXXCBL380HDHD
Expander to
Backplanes: cables
included with
Expander kit
Controller to
Expander: 1x
AXXCBL650HDHD
Expander to
backplanes:
Cables included
with Expander kit
Controller to
Expander: 1x
AXXCBL650HDMS
Expander to
backplanes:
Cables included
with Expander kit
6 October, 2014