Enclosure Management Cabling for Intel C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures
Enclosure Cabling Guide for Intel® C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures
Board
Drive
Numbe
r &
Type
Fixed or
hot-
swap
Types of
Drives
Supported
2
Drive kit required
Expander
required
Required Cabling if
using On-board
SATA Capable
Controller
Required Cabling if
using On-board SAS
Controller on
S2600CW2S or
S2600CWTS
Required Cabling if
using 12Gb/s RAID
Controller
1
Required Cabling if
using 6Gb/s RAID
Controller
1
S2600CW
8x2.5”
Hot
Swap
SATA +
SAS
FUP8X25S3HSDK
(with SAS only
HSBP
FXX8X25S3HSBP)
N/A
1x
AXXCBL380HDHD
1x
AXXCBL380HDHD
1x
AXXCBL650HDHD
1x
AXXCBL650HDMS
Hot
Swap,
NVMe
support
Up to 4x
2.5” NVMe
drives, Up
to 8
SATA/SAS
drives
(total 8
drives)
1x
FUP8X25S3NVDK
(with Combo
HSBP)
N/A
Up to 4 NVMe
drives: cables
included in NVMe
kit
FUP8x25S3NVDK
Up to 8 SATA/SAS
drives:
1x
AXXCBL380HDHD
Up to 4 NVMe
drives: cables
included in NVMe
kit
FUP8x25S3NVDK
Up to 8 SATA/SAS
drives:
1x
AXXCBL380HDHD
1x
AXXCBL650HDHD
1x
AXXCBL650HDMS
16x2.5”
Fixed
N/A, max 8x2.5” fixed drives
October, 2014 5