Specification Update
Monthly Specification Update Enterprise Platforms and Services Marketing
16
32.
InfiniBand* ConnectX* -3 I/O Module may not comply with FCC and
Industry Canada regulations
Problem Intel® FDR InfiniBand* ConnectX* -3 I/O Module AXX1FDRIBIOM and
AXX2FDRIBIOM may not comply with Part 15 of the Federal Communications
Commission (FCC) and Industry Canada regulations when used with copper
InfiniBand* cables.
Implication Except for not complying with FCC and Industry Canada regulations when used
with copper InfiniBand* cables, no other functionality impact. And except for the
United States of America and Canada where the regulations apply, no other
countries are impacted.
Status This issue may be fixed by hardware improvement in the future.
Workaround This product must be used with optical cables in the United States of America
and Canada to comply with FCC and Industry Canada regulations.
33.
The Intel
®
Xeon Phi™ Coprocessor PCI Express* Card Status Sensor may
show "Unknown"
Problem When only one Intel® Xeon Phi™ Coprocessor PCI Express* Card (MIC card)
is installed in the server system, the card status sensor “MIC 1 Status” or “MIC
2 Status” may show “Unknown” in Intel® Integrated BMC Web Console.
Implication Users may not get the correct MIC status in Intel® Integrated BMC Web
Console. There is no function impact to the server system. This issue doesn’t
happen when two Intel® Xeon Phi™ Coprocessor PCI Express* Cards are
installed.
Status This issue was fixed in BMC release 1.19.4926 or later.
Workaround None.
34.
The Intel
®
Xeon Phi™ Coprocessor PCI Express* Card sensors numbering
may not be consistent with riser slot numbering
Problem The Intel® Xeon Phi™ Coprocessor PCI Express* Card (MIC card) sensors
numbering may not be consistent with riser slot numbering on the server board.
When a Intel® Xeon Phi™ Coprocessor PCI Express* Card is installed in the
server system, in Intel® Integrated BMC Web Console, the card sensor may
show “MIC 2 Status” and “MIC 2 Margin” if the card is installed on “RISER
SLOT_1” and “MIC 1 Status” and “MIC 1 Margin” if the card is installed on
“RISER SLOT_2”.
Implication Users need to read MIC 2 sensors for a card installed on “RISER SLOT_1” and
read MIC 1 sensors for a card installed on “RISER SLOT_2”. There is no
function impact to the server system.