Specification Update

Monthly Specification Update Enterprise Platforms and Services Marketing
8
Workaround None.
10. Extra events may be seen in the System Event Log (SEL) during
system global reset
Problem The BMC may sporadically log extra reset event during a system DC reset
(global reset). These events may appear as there is an extra reset during BIOS
POST.
The following SEL entries indicate two resets in a POST process:
Informational event: Pwr Unit Status reports the power unit is powered off or
being powered down.
Informational event: Pwr Unit Status reports the power unit is powered off or
being powered down.
Implication The SEL log may indicate that system has an occasional reset in a normal
POST during DC cycle test (global reset).
Status This issue was fixed in BMC 1.04.
Workaround None.
11. System may continuously report a faulty or assert/deassert log
when having blank HDD carriers or un-configured HDDs
Problem With ESRT2 SATA RAID 5 config with 3 HDDs, put the 4th HDD in drive carrier
and set it to either unconfigured or global hot spare. System event log may be
flooded with HDD faulty entries.
With ESRT2 SAS RAID 1 with 2 HDDs, put 3rd HDD and set to unconfigured or
global hot spare. System event log may be flooded flood with HDD faulty
entries.
Implication User may see the SEL flooded with HDD faulty entries when either of the two
scenarios above are used.
Status This issue was fixed in BMC 1.04.
Workaround None.