Service Guide
Hardware Installations and Upgrades
Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide 51
Installing 8x3.5” Hot-swap Hard Drive Cage Assembly
CAUTION
It is critical that you connect the SAS/SATA data cables correctly from the SAS/SATA backplane to
your server board or RAID controller card. Failure to do so may result in data loss.
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel if it is installed. For instructions, see “Removing the Front Bezel (Pedestal
Only)”.
5. Remove the Fixed HDD EMI Shield and Fixed HDD Tray if they are installed. For instructions, see
“Removing the Fixed HDD Tray” and “Removing the Fixed HDD EMI Shield”
6. Install the 8x3.5” Hot-Swap Hard Drive Cage.
i. Slide the 8x3.5” Hot-Swap Drive Cage into the slot (see letter A).
ii. Secure the Hard Drive Cage with the Screw (see letter B).
Figure 65. Installing the 8x3.5” Hot-Swap Hard Drive Cage Assembly