Service Guide

BIOS Setup Utilities
178 Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide
13. Plug & Play BMC Detection
Option Values: Enabled
Disabled
Help Text:
If enabled, the BMC will be detectable by OSes which support plug and play loading of
an IPMI driver. Do not enable this option if your OS does not support this driver.
Comments: This option controls whether the OS Server Management Software will be able to
find the BMC and automatically load the correct IPMI support software for it. If your OS does
not support Plug & Play for the BMC, you will not have the correct IPMI driver software loaded.
14. EuP LOT6 Off-Mode
Option Values: Enabled
Disabled
Help Text:
Enable/disable Ecodesign EuP LOT6 “Deep Sleep” Off-Mode for near-zero energy use
when powered off.
Comments: This option controls whether the system goes into “Deep Sleep” or more
conventional S5 “Soft-Off” when powered off. “Deep Sleep” state uses less energy than S5, but
S5 can start up faster and can allow a Wake on LAN action (which cannot be done from a Deep
Sleep state).
This option will not appear on platforms which do not support EuP LOT6 Off-Mode. For details
on which platform do support it.
15. Shutdown Policy
Option Values: Enabled
Disabled
Help Text: Enable/Disable Shutdown Policy.
Comments: This option is designed for multiple-node system and to control the
policy that BMC should shutdown one node if it detected over-current or over-temperature
condition. The BIOS and the BMC will synchronize the policy during the BIOS POST and
current value of the BMC will be displayed in BIOS Setup.
This option is only displayed when the BMC support this feature on the node.
16. Console Redirection