Service Guide

BIOS Setup Utilities
162 Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide
Option Values: 10 seconds
20 seconds
30 seconds
40 seconds
Help Text:
USB Mass Storage device Start Unit command timeout.
Setting to a larger value provides more time for a mass storage device to be ready, if
needed.
Comments: If the USB controller setting is Disabled, this field is grayed out and
inactive.
7. Mass Storage Devices:
Option Values: Auto
Floppy
Forced FDD
Hard Disk
CD-ROM
Help Text:
[Auto] - USB devices less than 530 MB are emulated as floppies.
[Forced FDD] - HDD formatted drive is emulated as an FDD (for example, ZIP drive).
Comments: This field is hidden if no USB Mass Storage devices are detected.
This setup screen can show a maximum of eight USB Mass Storage devices on the screen. If
more than eight devices are installed in the system, the ‘USB Devices Enabled’ displays the
correct count, but only the first eight devices discovered are displayed in this list.
If the USB controller setting is Disabled, this field is grayed out and inactive.
System Acoustic and Performance Configuration
The System Acoustic and Performance Configuration screen allows the user to configure the
thermal control behavior of the system with respect to what parameters are used in the system’s Fan
Speed Control algorithms.
To access this screen from the Main screen, select Advanced > System Acoustic and Performance
Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen,
then select the desired screen.