Technical Product Specification
Appendix C: Platform Specific BMC Appendix Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
152 Intel order number G34153-004 Revision 1.4
Fan Domain Definition
Table 80. Intel
®
Workstation Board W2600CR – Fan Domain Definition
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
P4304 (UPL
with fixed
fan 4U)
0
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
System Fan 1(30h)
1
BB P2 VR Temp(24h)
BB MEM VR Temp(25h)
Exit Air Temp(2Eh)
HDD 20 Status(64h)
HDD 21 Status(65h)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
DIMM Thrm Mrgn 4(B3h)
System Fan 2(31h)
6
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
Processor 1 Fan(36h)
7
BB P2 VR Temp(24h)
Exit Air Temp(2Eh)
P2 Therm Margin(75h)
Processor 2 Fan(37h)
HSC Availability
Not supported.
Power Unit Support
Intel
®
Server Chassis P4304 (UPL)
Table 81. Intel
®
Server Chassis P4304 (UPL) Power Support
PS Module
Number
PMBus*
Product Name (in
product area of the
FRU)
PSU Redundant
Cold
Redundant
Fans in each
PS
750W HS Power
Supply
Supported
DPS-750XB A
Supported
Supported
1 PS fan
1200W HS
Power Supply
Supported
DPS-1200TB A
Supported
Supported
2PS fan