Technical Product Specification
Appendix C: Platform Specific BMC Appendix Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
146 Intel order number G34153-004 Revision 1.4
Fan Redundancy Support
Supported on:
Intel
®
Server Chassis P4208 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4216 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4224 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4308 (UPL with redundant fan 4U)
Intel
®
Server Chassis P4XXX (UPL with redundant fan 4U)
Intel
®
Server Chassis R2208 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2216 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2224 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2308 (BHP with redundant fan 2U)
Intel
®
Server Chassis R2312 (BHP with redundant fan 2U)
Fan Domain Definition
Table 75. Intel
®
Server Board S2600IP – Fan Domain Definition
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
P4208/P4216/P4224/P4
308/P4XXX (UPL with
redundant fan 4U)
0
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
System Fan 1(30h)
1
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
System Fan 2(31h)