Technical Product Specification

Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-004 Revision 1.4
140
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Global Aggregate
Temperature
Margin 8
(Agg Therm Mrgn
8)
CFh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Baseboard +12V
(BB +12.0V)
D0h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +5V
(BB +5.0V)
D1h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +3.3V
(BB +3.3V)
D2h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +5V
Stand-by
(BB +5.0V STBY)
D3h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard +3.3V
Auxiliary
(BB +3.3V AUX)
D4h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard +1.05V
Processor1 Vccp
(BB +1.05Vccp P1)
D6h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.05V
Processor2 Vccp
(BB +1.05Vccp P2)
D7h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A