Technical Product Specification
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-004 Revision 1.4
136
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 4 VRD
Temperature
(P4 VRD Hot)
93h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Fatal
As and
De
–
Trig
Offset
M
–
Processor 1
Memory VRD Hot
0-1
(P1 Mem01 VRD
Hot)
94h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 1
Memory VRD Hot
2-3
(P1 Mem23 VRD
Hot)
95h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 2
Memory VRD Hot
0-1
(P2 Mem01 VRD
Hot)
96h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 2
Memory VRD Hot
2-3
(P2 Mem23 VRD
Hot)
97h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 3
Memory VRD Hot
0-1
(P3 Mem01 VRD
Hot)
98h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 3
Memory VRD Hot
2-3
(P4 Mem23 VRD
Hot)
99h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 4
Memory VRD Hot
0-1
(P4 Mem01 VRD
Hot)
9Ah
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–