Technical Product Specification

Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-004 Revision 1.4
132
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Power Supply 1
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 2
AC Power Input
(PS2 Power In)
55h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 1
+12V % of
Maximum Current
Output
(PS1 Curr Out %)
58h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 2
+12V % of
Maximum Current
Output
(PS2 Curr Out %)
59h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 1
Temperature
(PS1 Temperature)
5Ch
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 2
Temperature
(PS2 Temperature)
5Dh
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Hard Disk Drive 16
- 24 Status
(HDD 16 - 24
Status)
60h
68h
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 - Drive Presence
OK
As and
De
Trig
Offset
A
X
01- Drive Fault
Degraded
07 - Rebuild/Remap in
progress
Degraded