Technical Product Specification

Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-004 Revision 1.4
128
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
BMC Firmware
Health
(BMC FW Health)
10h
All
Mgmt Health
28h
Sensor
Specific
6Fh
04 Sensor Failure
Degraded
As
-
Trig
Offset
A
X
System Airflow
(System Airflow)
11h
All
Other Units
0Bh
Threshold
01h
Analog
FW Update Status
12h
All
Version
Change 2Bh
OEM defined
x70h
00hUpdate started
01hUpdate
completed
successfully.
02hUpdate failure
OK
As
_
Trig
Offset
A
_
IO Module2
Presence
(IO Mod2
Presence)
13h
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present
OK
As and
De
Trig
Offset
M
-
Baseboard
Temperature 5
(Platform Specific)
14h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard
Temperature 6
(Platform Specific)
15h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
IO Module2
Temperature
(I/O Mod2 Temp)
16h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
PCI Riser 3
Temperature
(PCI Riser 5 Temp)
17h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X