Technical Product Specification

Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.4 Intel order number G34153-004
137
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 4
Memory VRD Hot
2-3
(P4 Mem23 VRD
Hot)
9Bh
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Power Supply 1
Fan Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted
Non-fatal
As and
De
-
Trig
Offset
M
-
Power Supply 1
Fan Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted
Non-fatal
As and
De
-
Trig
Offset
M
-
Power Supply 2
Fan Tachometer 1
(PS2 Fan Tach 1)
A4h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted
Non-fatal
As and
De
-
Trig
Offset
M
-
Power Supply 2
Fan Tachometer 2
(PS2 Fan Tach 2)
A5h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted
Non-fatal
As and
De
-
Trig
Offset
M
-
Processor 1 DIMM
Aggregate Thermal
Margin 1
(P1 DIMM Thrm
Mrgn1)
B0h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 1 DIMM
Aggregate Thermal
Margin 2
(P1 DIMM Thrm
Mrgn2)
B1h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 2 DIMM
Aggregate Thermal
Margin 1
(P2 DIMM Thrm
Mrgn1)
B2h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 2 DIMM
Aggregate Thermal
Margin 2
(P2 DIMM Thrm
Mrgn2)
B3h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A