7
Implication User may see the SEL flooded with RAID volume rebuild event entries.
Status This issue was fixed in the latest RSTe driver ver 3.0.0.3020 upd 2012.02.03.
Workaround None.
7. System may halt under specific BIOS configurations
Problem Once BIOS options “EFI Optimized Bootand “Memory Mapped I/O Above
4GB” are enabled, and RSTe mode is selected, system may halt during POST.
Implication User may see system hang with the above mentioned configuration.
Status This issue was fixed in Bios 01.03.0002 release.
Workaround None.
8. Microsoft Windows 2003* x86 installation failure occurs using
the “Pass-Throughmode of the SCU controller
Problem Microsoft Windows Server 2003* x86 installations on SCU RSTe pass-
throughmode fail.
Implication User may not able to install Microsoft Windows Server 2003* x86 on the above
mentioned BIOS configuration.
Status This issue may be fixed in a future RSTe driver release.
Workaround None.
9. System may halt under unsupported configuration in ESRT2
mode
Problem If no Intel
®
C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8,
RKSAS8R5) is installed to enable SAS support capablity under the ESRT2
mode and SAS drivers are used, the system may halt at the boot stage.
Implication User may see a system halt with no RAID keys installed with SAS drivers used
and ESRT2 enabled. User should use SATA drives only if no RAID key
installed.
Status This issue was fixed in Bios01.03.0002 BIOS release.