Technical Product Specification
Intel® Server System P4000IP and Intel® Workstation System P4000CR Family TPS Environmental Limits
Revision 1.2 Intel order number G38159-002
99
6. Environmental Limits
6.1 System Environment Limits
The following table defines the Intel
®
Server System P4000IP and Intel
®
Workstation System
P4000CR system level operating and non-operating environmental limits. Operation of the
Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR at conditions beyond
those shown in the following table may cause permanent damage to the system. Exposure to
absolute maximum rating conditions for extended periods may affect system reliability.
Table 107. System Environment Limits Summary
Parameter
Limits
Temperature
Operating
ASHRAE Class A2 – Continuous Operation. 10º C to 35º C (50º F to 95º F) with
the maximum rate of change not to exceed 10°C per hour
ASHRAE Class A3 – Includes operation up to 40C for up to 900 hrs per year.
ASHRAE Class A4 – Includes operation up to 45C for up to 90 hrs per year.
Shipping
-40º C to 70º C (-40º F to 158º F)
Altitude
Operating
Support operation up to 3050m with ASHRAE class deratings.
Humidity
Shipping
50% to 90%, non-condensing with a maximum wet bulb of 28° C (at
temperatures from 25° C to 35° C)
Shock
Operating
Half sine, 2g, 11 mSec
Unpackaged
Trapezoidal, 25g, velocity change is based on packaged weight
Packaged
Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
Vibration
Unpackaged
5 Hz to 500 Hz 2.20 g RMS random
Packaged
5 Hz to 500 Hz 1.09 g RMS random
AC-DC
Voltage
90 Hz to 132 V and 180 V to 264 V
Frequency
47 Hz to 63 Hz
Source
Interrupt
No loss of data for power line drop-out of 12 mSec