S2600GZ and S2600GL

Table Of Contents
Appendix B: Integrated BMC Sensor Tables Intel® Server Board S2600GZ/GL TPS
Note: All sensors listed below may not be present on all platforms. Please check platform EPS section for platform applicability and
platform chassis section for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate
hardware to support redundancy (for instance, fan or power supply)
Table 61. BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Readi
ng Type
Event Offset Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Of
fsets
Event
Data
Rearm
Stand-
by
Power Unit Status
(Pwr Unit Status)
01h All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
OK
As
and
De
Trig Offset A X
02 - 240 VA power
down
Fatal
04 - A/C lost
OK
05 - Soft power
control failure
Fatal
06 - Power unit failure
Power Unit Redundancy
Note1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully Redundant
OK
As
and
De
Trig Offset A X
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal
Revision 2.4
198